Production equipment uptime and serviceability directly impact battery manufacturing throughput. The XWELL XW-5V300A16CH Prismatic Battery Cell Grading Machine employs a modular design concept across its 16-channel architecture, with each channel functioning as an independent constant current and constant voltage source. This modular approach, combined with a human-machine interface that provides intuitive graphical operation and per-channel status indication, supports maintenance procedures and production workflow continuity. The equipment integrates STM32 microcontroller control, bidirectional power supply technology, and comprehensive protection functions within this modular framework.
The XW-5V300A16CH uses a modular design concept where each of the 16 channels operates as an independent functional unit. This modular architecture supports maintenance procedures by allowing individual channel service access without requiring complete system disassembly.
Each channel is built as a single-point independent constant current and constant voltage source. Channel independence means that individual channels can be serviced or replaced while the remaining channels continue testing operations, supporting production uptime requirements.
The software interface is designed with user accessibility in mind, featuring a graphical operation display that shows voltage, current, time, and capacity data simultaneously for all 16 channels. Color-coded status indication provides immediate visual feedback on each channel's operating condition.
The power stage employs field effect transistors (FETs) selected for their suitability with lower voltage discharge applications, including lithium iron phosphate (LiFePO4) batteries. This component selection supports the bidirectional power supply design and energy feedback regeneration function.
The system performs real-time detection and display of each battery's status across all channels. When an abnormality is detected, the affected channel stops operation and activates its indicator light, while the graphical interface provides visual indication of the fault condition.
The equipment includes power failure protection that preserves the operational state and test data. After power restoration, the system continues the original workflow from the interruption point, supporting unattended operation during extended grading cycles.
| Parameter | Specification |
|---|---|
| Power Supply | AC380±10%/50Hz/3P |
| Power | ≤30KW |
| Channels | 16 channels |
| Charge/Discharge Voltage Range | DC 0mV~4.5V / DC 2V~4.5V |
| Constant Voltage Range | DC 2~4.5V |
| Voltage Measurement Range | DC 0V~5V |
| Charge/Discharge Current Range | 600mA~300A |
| Voltage Measurement Control Accuracy | ±(0.5‰ reading + 0.5‰ full scale) |
| Current Measurement Control Accuracy | ±(0.5‰ reading + 0.5‰ full scale) |
| Voltage Resolution | 0.1mV |
| Current Resolution | 1mA |
| Time Measurement Control Accuracy | ≤±0.1% |
| Charge/Discharge Mode | Constant current, constant voltage, constant current constant voltage, constant power, constant resistance |
| Charging Cut-Off Condition | Voltage, current, time, capacity, -ΔV |
| Discharge Cut-Off Condition | Voltage, time, capacity |
| Process Settings | 64 process step parameters and 256 cycles can be set |
| Cell Specification | Pole distance: 50-170mm; Length: 90-220mm; Thickness: 15-100mm; Height: 80-310mm |
| Control Method | Computer control equipment operation, whole cabinet control, with scanning system |
| Protection | Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity protection, power failure protection, data breakpoint recovery |
| Device Size | L1120*W1420*H1909mm |
The XW-5V300A16CH is applicable for prismatic battery cell grading and testing in electric vehicle battery production facilities, energy storage system manufacturing lines, and industrial lithium battery quality control operations where equipment serviceability and production continuity are important operational considerations.