| Brand Name: | XWELL |
| Model Number: | XW-5V300A16CH |
| MOQ: | 1 Set |
| Price: | Contact for Pricing |
| Packaging Details: | Wooden Case Export Packaging |
| Payment Terms: | T/T, L/C, Western Union |
Continuous battery cell testing operations require equipment with integrated protection mechanisms to prevent cell damage and data loss during extended grading cycles. The XWELL XW-5V300A16CH Prismatic Battery Cell Grading Machine incorporates a multi-layer protection system covering overvoltage, undervoltage, overcurrent, undercurrent, and overcapacity conditions, along with power failure protection and data breakpoint recovery. These protection functions operate on a per-channel basis across the 16-channel configuration, allowing individual channels to halt safely while remaining channels continue testing uninterrupted.
The XW-5V300A16CH monitors each of its 16 channels for overvoltage, undervoltage, overcurrent, undercurrent, and overcapacity conditions. When an abnormal parameter is detected, the affected channel automatically stops operation and signals the condition through an indicator light, while unaffected channels maintain their testing programs.
A power failure protection function preserves the current operational state and all accumulated test data during power interruptions. Upon power restoration, the system automatically resumes the original testing workflow from the interruption point, eliminating the need to restart grading cycles.
The data breakpoint recovery mechanism ensures that all test data—including voltage, current, time, and capacity measurements recorded at 1-second intervals—is preserved through power interruptions. The system reconstructs the operational state at the point of interruption for seamless continuation.
The graphical operation interface displays the status of each battery under test simultaneously, using configurable color coding to differentiate normal operation, charging, discharging, and fault conditions. This visual monitoring supports rapid identification of channel states during production-scale testing.
Charging cut-off conditions can be configured by voltage, current, time, capacity, or -ΔV parameters. Discharge cut-off conditions support voltage, time, and capacity settings, providing flexible end-point control for various battery testing protocols across all 16 channels.
Each of the 16 channels operates as an independent constant current and constant voltage source. When a fault is detected on one channel, only that channel stops while others continue, supporting uninterrupted production testing workflows.
| Parameter | Specification |
|---|---|
| Power Supply | AC380±10%/50Hz/3P |
| Power | ≤30KW |
| Channels | 16 channels |
| Charge/Discharge Voltage Range | DC 0mV~4.5V / DC 2V~4.5V |
| Constant Voltage Range | DC 2~4.5V |
| Voltage Measurement Range | DC 0V~5V |
| Charge/Discharge Current Range | 600mA~300A |
| Voltage Measurement Control Accuracy | ±(0.5‰ reading + 0.5‰ full scale) |
| Current Measurement Control Accuracy | ±(0.5‰ reading + 0.5‰ full scale) |
| Voltage Resolution | 0.1mV |
| Current Resolution | 1mA |
| Time Measurement Control Accuracy | ≤±0.1% |
| Charge/Discharge Mode | Constant current, constant voltage, constant current constant voltage, constant power, constant resistance |
| Charging Cut-Off Condition | Voltage, current, time, capacity, -ΔV |
| Discharge Cut-Off Condition | Voltage, time, capacity |
| Process Settings | 64 process step parameters and 256 cycles can be set |
| Cell Specification | Pole distance: 50-170mm; Length: 90-220mm; Thickness: 15-100mm; Height: 80-310mm |
| Control Method | Computer control equipment operation, whole cabinet control, with scanning system |
| Protection | Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity protection, power failure protection, data breakpoint recovery |
| Device Size | L1120*W1420*H1909mm |
| Cell Parameter | Supported Range |
|---|---|
| Pole Distance | 50-170mm |
| Length | 90-220mm |
| Thickness | 15-100mm |
| Height | 80-310mm |
The dimensional range supports prismatic lithium battery cells commonly used in electric vehicle battery packs, energy storage systems, and industrial power applications. The equipment is compatible with various prismatic cell chemistries within the specified voltage and current ranges.
The XW-5V300A16CH is designed for prismatic battery cell grading and testing in production environments that require continuous, unattended operation. Applications include electric vehicle battery cell quality control, energy storage battery production testing, and industrial lithium battery manufacturing lines where protection and data integrity are critical.
For specifications, pricing, and ordering details for the XW-5V300A16CH Prismatic Battery Cell Grading Machine, contact GUANGDONG XWELL TECHNOLOGY CO., LTD.
Website: https://xwellcn.com | Email: sales@xwellcn.com | TEL/WhatsApp/WeChat: +86-18620492985