70V Aging Cabinet Lithium Battery Pack 5A Charging 10A Discharging Aging Tester

70V Aging Cabinet Lithium Battery Pack 5A Charging 10A Discharging Aging Tester

Brand Name: XWELL
Model Number: BCDS70-05-10
MOQ: 1pcs
Price: USD 2000/pcs
Packaging Details: Wooden box
Payment Terms: T/T, Western Union, L/C
Detail Information
Place of Origin:
China
Certification:
CE
Compliance:
CE Certified
Type:
Semi-Automatic
Power Supply:
AC220V 50Hz
Charging Accuracy:
±(0.2% Of Reading +0.2% Of Range)
Discharge Range:
50-10000mA
Discharge Accuracy:
±(0.2% Of Reading +0.2% Of Range)
Constant Voltage Cut-off Current:
Minimum 50mA
Discharge Power:
≤700W
Inspection Time:
Real-time Collection<2S
Supply Ability:
100 pcs per month
Highlight:

70V lithium battery aging cabinet

,

5A charging battery tester

,

10A discharging aging machine

Product Description

70V Aging Cabinet Lithium Battery Pack 5A Charging 10A Discharging Aging Tester

 

Features

 

 

*Designed for 18650,21700, 26650,32650,32700...lithium battery pack charge and discharge testing and aging after assembling.

*Suitable for: electric bicycle, swing bike, scooter, electric motorcycle, solar energy storage, large capacity energy storage, power tools battery pack

*Charging: Constant current and voltage charging

* Discharge: Constant current discharge

*Checking charging and discharging protection function

*Charging and discharging capacity recording

*Serial port and network connection function

*Computer online monitor, can manage max 254 point

*Store testing data in MYSQL, can review at any time

 

 

Product Specification

 

Technical Parameter

 

Input Power Supply

Measuring Range 7-70V
  Accuracy ±(0.2% of reading +0.2% of range)

 

 

Current

 

 

 

 

 

 

Charging Range 50-5000mA
Charging Accuracy ±(0.2% of reading +0.2% of range)
Discharge Range 50-10000mA
Discharge Accuracy ±(0.2% of reading +0.2% of range)
Charge Constant Voltage Cut-off Current Minimum 50mA
Capacity Accuracy ±1%
Power Discharge Power ≤700W
Time Inspection Time Real-time Collection<2S
  Timing Range 0-999h/step
Data Recording Interval ≥5S
Middle Machine Version 1:1 series
Number of Passages Per Cabinet 12 channels, four rows and three column  

Charge

 

Charging Mode Constant Current and Constant Voltage Charging
Cut-off condition Voltage, Current, Relative Time, Overcharge Protection
Discharge Discharge mode Constant current discharge
  Cut-off condition Voltage, Relative Time and Over-discharge Protection
Loop Cyclic measurement range 1-999 times
  Single cycle step number 100
Voltage and Current Detection Sampling Four-wire sampling
Data Base Using SQL database to manage test data
Upper computer communication mode Based on TCP/IP Protocol/Serial Port
Data Output Mode EXCEL/TXT/Chart
Communication Interface Mesh port
Chassis dimensions 300x450x170mm
Cabinet size 900x600x1900mm
Spatial Dimension of Discharge Battery 900x600x130mm