32 Channel 5V 120A Capacity Grading Machine For Prismatic Cell Battery Life Discharge Charge Tester
Product Details:
Place of Origin: | China |
Brand Name: | XWELL |
Certification: | CE |
Model Number: | XW-32 |
Payment & Shipping Terms:
Minimum Order Quantity: | 1pcs |
---|---|
Price: | USD 7900/pcs |
Packaging Details: | Wooden box |
Delivery Time: | 15-20 days |
Payment Terms: | T/T, Western Union, L/C |
Supply Ability: | 100 pcs per month |
Detail Information |
|||
Charge Discharge Current: | 120A | Total Channels Number: | 32 |
---|---|---|---|
Voltage And Current: | 5V/10A; 5V/20A; 5V/30A | Heat Dissipation: | To Enter The Air Naturally And Exhaust The Air Upward |
Overall Energy Saving: | Over 70% | Voltage Measuring Range: | 0-5V, 1MV Resolution |
Battery Voltage Range: | Charge 0-4.5V: Discharge 4.5-2V | Voltage Accuracy: | ±(1‰ Reading +1‰ Full) |
Control Mode: | Computer Connection Equipment Work, FCL Control | ||
Highlight: | Prismatic Cell Battery Cell Grading Machine,5V Battery Cell Grading Machine,120A Battery Cell Grading Machine |
Product Description
32 Channel 5V 120A Capacity Grading Machine For Prismatic Cell Battery Life Discharge Charge Tester
Product Features
stable operation, selected materials, fine craftsmanship, higher service life than peers, and fast inspection speed.
2.Technical excellence: The feeder-type energy-saving mode design is adopted, which has high energy-saving efficiency,
flexibility, and humanized intelligent operation. The product linearity, accuracy and speed have reached high standards, and the
maintenance and upgrades are good for expansion.
Software function
B) Automatically calculate constant current charging ratio, capacity loss, discharge efficiency, average voltage, median voltage
and other data;
C) Set operator authority and operate in different levels;
E) Display charge discharge curve and cycle chart;
(We can provide 5V 2A 3A 5A 6A 512 Channel Battery Charging and Discharging Machine according to your request.)
Product Specification
Working power | Three-phase five-wire system AC380V±10%, 50HZ | ||
Work environment | Temperature 0-40 degrees, relative humidity ≤80% | ||
Heat dissipation | to enter the air naturally and exhaust the air upward | ||
Overall energy saving | over 70% | ||
Channel Parameter | |||
Voltage measuring range | 0-5V, 1MV resolution | ||
Battery voltage range | Charge 0-4.5V: Discharge 4.5-2V | ||
Constant voltage range | 2.5V-4.5V | ||
voltage accuracy | ±(1‰ reading +1‰ full) | ||
Current accuracy | ±(1‰ reading +1‰ full) | ||
Software Function | |||
Control mode | Computer connection equipment work, FCL control | ||
Communication mode | RS485 baud rate 57,600 | ||
Process set | A maximum of 32 work steps and 256 cycles are se | ||
Charging mode | Constant current, constant pressure | ||
Charging cutoff condition | Voltage, current, time, capacity | ||
Discharge | constant current | ||
Discharge cut-off condition | Voltage, time, capacity | ||
Defensive function | Overvoltage, undervoltage, overcurrent, undercurrent, overcapacity, etc | ||
Time range | Set it anywhere from 0 to 30,000 minutes | ||
Time accuracy | ≤±1‰ | ||
Sampling inspection period | ≤3S | ||
Minimum frequency of data recording | ≤5S | ||
Battery sorting | By capacity, time, discharge platform, etc | ||
Data processing | Data, graphs, and loop diagrams |