Battery Charge And Discharge Aging Machine
Product Details:
Place of Origin: | China |
Brand Name: | XWELL |
Certification: | CE |
Model Number: | BCDS70-05-10 |
Payment & Shipping Terms:
Minimum Order Quantity: | 1pcs |
---|---|
Price: | USD 2000/pcs |
Packaging Details: | Wooden box |
Delivery Time: | 15-20 days |
Payment Terms: | T/T, Western Union, L/C |
Supply Ability: | 100 pcs per month |
Detail Information |
|||
Max Charge Current: | 5A | Max Discharge Current: | 20A |
---|---|---|---|
Charging Range: | 50-5000mA | Charging Accuracy: | ±(0.2% Of Reading +0.2% Of Range) |
Discharge Range: | 50-10000mA | Discharge Accuracy: | ±(0.2% Of Reading +0.2% Of Range) |
Constant Voltage Cut-off Current: | Minimum 50mA | Discharge Power: | ≤700W |
Inspection Time: | Real-time Collection<2S | ||
Highlight: | Battery Charge Aging Machine,Battery Discharge Aging Machine,Battery Charge Discharge Aging Machine |
Product Description
Battery Charge And Discharge Aging Machine
The Battery Pack Charge and Discharge Aging Machine is mainly used for the charge and discharge cycle test of the finished lithium battery.
The test items include: battery charge protection voltage, discharge protection voltage, battery capacity, etc.; the equipment has 4 test steps of charging, discharging, shelving, and cycling. You can make the battery test in accordance with the set process.
The test functions are:
1) Battery charge protection voltage
2) Discharge protection voltage
3) Battery capacity
Product Specification
Technical Parameter | ||
Input Power Supply |
Measuring Range | 7-70V |
Accuracy | ±(0.2% of reading +0.2% of range) | |
Current
|
Charging Range | 50-5000mA |
Charging Accuracy | ±(0.2% of reading +0.2% of range) | |
Discharge Range | 50-10000mA | |
Discharge Accuracy | ±(0.2% of reading +0.2% of range) | |
Charge | Constant Voltage Cut-off Current | Minimum 50mA |
Capacity | Accuracy | ±1% |
Power | Discharge Power | ≤700W |
Time | Inspection Time | Real-time Collection<2S |
Timing Range | 0-999h/step | |
Data Recording Interval | ≥5S | |
Middle Machine Version | 1:1 series | |
Number of Passages Per Cabinet | 12 channels, four rows and three column | |
Charge
|
Charging Mode | Constant Current and Constant Voltage Charging |
Cut-off condition | Voltage, Current, Relative Time, Overcharge Protection | |
Discharge | Discharge mode | Constant current discharge |
Cut-off condition | Voltage, Relative Time and Over-discharge Protection | |
Loop | Cyclic measurement range | 1-999 times |
Single cycle step number | 100 | |
Voltage and Current Detection Sampling | Four-wire sampling | |
Data Base | Using SQL database to manage test data | |
Upper computer communication mode | Based on TCP/IP Protocol/Serial Port | |
Data Output Mode | EXCEL/TXT/Chart | |
Communication Interface | Mesh port | |
Chassis dimensions | 300x450x170mm | |
Cabinet size | 900x600x1900mm | |
Spatial Dimension of Discharge Battery | 900x600x130mm |