Charge And Discharge Li Ion Battery Aging Test Machine For Battery Pack
Product Details:
Place of Origin: | China |
Brand Name: | XWELL |
Certification: | CE |
Model Number: | BCDS70-05-10 |
Payment & Shipping Terms:
Minimum Order Quantity: | 1pcs |
---|---|
Price: | USD 2000/pcs |
Packaging Details: | Wooden box |
Delivery Time: | 15-20 days |
Payment Terms: | T/T, Western Union, L/C |
Supply Ability: | 100 pcs per month |
Detail Information |
|||
Place Of Origin: | Guangdong, China | Power Supply: | AC220V 50Hz |
---|---|---|---|
Charging Range: | 50-5000mA | Charging Accuracy: | ±(0.2% Of Reading +0.2% Of Range) |
Discharge Range: | 50-10000mA | Discharge Accuracy: | ±(0.2% Of Reading +0.2% Of Range) |
Constant Voltage Cut-off Current: | Minimum 50mA | Discharge Power: | ≤700W |
Inspection Time: | Real-time Collection<2S | ||
Highlight: | Battery Charge Aging Test Machine,Battery Discharge Aging Test Machine,Battery Pack Aging Test Machine |
Product Description
Charge And Discharge Li Ion Battery Aging Test Machine For Battery Pack
Function Features:
1) Single channel control technology, each channel is independent of each other
2) Anti-reverse connection protection function, data is automatically saved in real time
3) Two communication methods: serial port and network
4) Data output to Excel, TXT
Machine functions
2) Discharge protection voltage
3) Battery capacity
Product Specification
Technical Parameter | ||
Input Power Supply |
Measuring Range | 7-70V |
Accuracy | ±(0.2% of reading +0.2% of range) | |
Current
|
Charging Range | 50-5000mA |
Charging Accuracy | ±(0.2% of reading +0.2% of range) | |
Discharge Range | 50-10000mA | |
Discharge Accuracy | ±(0.2% of reading +0.2% of range) | |
Charge | Constant Voltage Cut-off Current | Minimum 50mA |
Capacity | Accuracy | ±1% |
Power | Discharge Power | ≤700W |
Time | Inspection Time | Real-time Collection<2S |
Timing Range | 0-999h/step | |
Data Recording Interval | ≥5S | |
Middle Machine Version | 1:1 series | |
Number of Passages Per Cabinet | 12 channels, four rows and three column | |
Charge
|
Charging Mode | Constant Current and Constant Voltage Charging |
Cut-off condition | Voltage, Current, Relative Time, Overcharge Protection | |
Discharge | Discharge mode | Constant current discharge |
Cut-off condition | Voltage, Relative Time and Over-discharge Protection | |
Loop | Cyclic measurement range | 1-999 times |
Single cycle step number | 100 | |
Voltage and Current Detection Sampling | Four-wire sampling | |
Data Base | Using SQL database to manage test data | |
Upper computer communication mode | Based on TCP/IP Protocol/Serial Port | |
Data Output Mode | EXCEL/TXT/Chart | |
Communication Interface | Mesh port | |
Chassis dimensions | 300x450x170mm | |
Cabinet size | 900x600x1900mm | |
Spatial Dimension of Discharge Battery | 900x600x130mm |