Singel Channel Battery Cell Testing Equipment 70V 5A Anti Reverse
Product Details:
Place of Origin: | China |
Brand Name: | XWELL |
Certification: | CE |
Model Number: | BCDS70-5-10 |
Payment & Shipping Terms:
Minimum Order Quantity: | 1pcs |
---|---|
Price: | USD 2000/pcs |
Packaging Details: | Wooden box |
Delivery Time: | 15-20 days |
Payment Terms: | T/T, Western Union, L/C |
Supply Ability: | 100 pcs per month |
Detail Information |
|||
Input AC: | AC 380V ±15%/50/60±5Hz | Output Power: | 24 KW |
---|---|---|---|
Input Current: | 42.9 A/Phase | Input Power: | 28.2 KW |
CV Output Range: | 3~70V | Min Discharge Voltage: | 3 V |
Accuracy: | ±(0.05% Of FS+0.05% Of RD) | Stability: | ± 0.1% Of FS |
Output Range/channel: | 0.5A~10A | ||
Highlight: | 70V battery capacity discharge tester,Anti Reverse battery cell testing equipment,Anti Reverse battery cell testing equipment |
Product Description
70V 5A 10A Singel Channel Lithium Cells Battery Pack Aging Cabinet Tester Charging And Discharging Ageing Machine
Product Description
The BCDS series aging cabinet is mainly used for the charge and discharge cycle test of the finished lithium battery. The test items include: battery charge protection voltage, discharge protection voltage, capacity, etc.; the equipment has 4 test steps of charging, discharging, shelving, and cycling By editing the corresponding steps, the battery can be tested according to the set process.
Product Features
Charging function: with constant current and constant voltage charging function
Discharge function: with constant current discharge function
Charge and discharge interface: fully meet the requirements of the same port and separate port for charging and discharging the
battery pack, that is, 2 wires (P+ P-) and 3 wires (P+ P- C-), and can age the positive electrode to protect the negative plate
from discharging Protection type power tool battery (CH+ P+ P-)
Check voltage protection: by charging and discharging the battery, can check whether the battery's charge protection and
discharge protection work.
Record the charge and discharge capacity: charge and discharge the battery, and record the charge and discharge capacity of the
battery.
Safety protection: anti-reverse connection protection function; voltage upper and lower limit setting protection; safe discharge
current protection.
Serial port connection mode: If the instrument is single or less than 3, it can be connected to the PC through the serial port,
which can reduce the complexity of using the instrument.
Network connection mode: If there are more than 3 instruments, the network connection mode can be used. The PC computer only
needs to provide a network port to control less than 60 instruments.
Control system: The software system of the aging instrument adopts the classic and mature C/S mode, and the communication mode is
serial port and network.
Management software: Based on Windows operating system, using SQL database to store test data, which greatly facilitates the
staff to query and export data online. According to the battery bar code, time, and device number, you can view the charge and
discharge aging curve, and you can also export the curve.
Product Advantages
1.In network mode, online automatically, no manual connection is required. 2.Use Mysql database to save data, to ensure that data will not be lost, provide measurement data back-check function. 3.A small number of instruments, you can communicate with PC software through serial port. 4.Many instruments can use network to communicate with PC software, reduce the computer interface, only one interface, you can control all instruments, to ensure the real-time and integrity of communication data. 5.The instrument provides P + and P-interfaces, as well as CH + and CH-, which can measure special finished batteries and charge and discharge on an instrument.
Product Specification
Input AC
|
AC 380V ±15%/50/60±5Hz
|
|
Output Power
|
24 KW
|
|
Input Current
|
42.9 A/Phase
|
|
Input Power
|
28.2 KW
|
|
Voltage
|
CV output range
|
3~70V
|
Min discharge voltage
|
3 V
|
|
Accuracy
|
±(0.02% of FS+0.02% of RD)
|
|
Stability
|
± 0.1% of FS
|
|
Current
|
Output range/channel
|
0.5A~10A
|
Accuracy
|
±(0.05% of FS+0.05% of RD)
|
|
CV cut-off current
|
0.2A
|
|
Stability
|
± 0.1% of FS
|
|
Power
|
Output power/channel
|
6KW
|
Stability
|
±0.2% of FS
|
|
Time
|
Current response time
|
Max rising time: 5ms (10% to 90% or 90% to 10%)
|
Working step time
|
≤(365*24)h/step, Time format-00:00:00.000(h,m,s,ms)
|
|
Data
record |
Data record
conditions |
Min data record interval:10ms (connected with AUX channel:100ms)
|
Min voltage change:0.12V
|
||
Min current change:0.2A
|
||
Frequency
|
100Hz (connected with AUX channel:10Hz)
|
|
Charge
|
Charge mode
|
Constant current, Constant voltage, Constant current and voltage, Constant power
|
Cut-off condition
|
Main channel:Voltage, Current, ΔTime, Capacity,-ΔV
|
|
Discharge
|
Discharge mode
|
Constant current, Constant power, Constant resistance
|
Cut-off condition
|
Main channel:Voltage, Current, ΔTime, Capacity
|
|
Pulse
Mode |
Charge
|
Constant current, Constant power
|
Discharge
|
Constant current, Constant power
|
|
Min pulse width
|
100ms
|
|
Pulse cycles
|
up to 32
|
|
Chg and Dischg switch
|
Supported
|
|
Cut-off condition
|
Voltage, Time
|
|
Simulation
|
Charge
|
Constant current, Constant power
|
Discharge
|
Constant current, Constant power
|
|
Cut-off condition
|
Time,Line number
|
|
Continuous switching Change and Dischange
|
One simulation step can realize continuous
switching from charging to discharging |
|
Limit step number
|
1 million
|
|
Cycle
|
Max cycles
|
65535
|
Max steps
|
254
|
|
Cycle nest
|
3
|
|
Protection
|
Power-off data protection
|
|
Off-line operation mode
|
||
User-defined protection conditions,
such as upper and lower limited current/voltage, delay time, temperature, etc. |
||
Efficiency of Charge and discharge
|
>85%
|
|
Protection level
|
IP20
|
|
Channels parallel
|
supported,
Parallel channels do not support pulse and simulation testing |
|
Channels feature
|
Independent pairs of closed loop for constant
|
|
Energy feedback
|
The discharge energy can be fed back to the grid
|
|
Channels control mode
|
Independent control
|
|
Noise
|
≤65dB
|
|
Database
|
MySQL
|
|
Communicatin
|
TCP/IP
|
|
Data export
|
EXCEL,TXT,CSV,PDF,Plot/Graph
|
|
Disk drive
|
500GB
|
|
Operating system
|
Windows 7/8/10 64 bit
|
|
Communication port
|
Ethernet port, CAN communication supports communication
with BMS to obtain cell voltage and temperature in BMS |
|
Items
|
Values
|
|
Number of channels
|
4
|
|
Dimensions(W*D*H)(mm)
|
W*D*H:600*800*1300(mm)
|
|
Working Environment requirement
|
||
Items
|
Values
|
|
Operation environment temperature
|
-10℃~45℃(When the temperature is 25±10℃,
the measurement accuracy is guaranteed: accuracy drift 0.005% of FS /℃) |
|
Storage environment temperature
|
-20℃~50℃
|
|
Operation environment humidity
|
≤70% RH(no moisture condensation)
|
|
Storage environment humidity
|
≤80% RH(no moisture condensation)
|
Want to Know more details about this product